Micro Motion RFT9709 Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Networking Micro Motion RFT9709. Micro Motion RFT9709 Instruction manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Model RFT9709
Transmitter
Instruction Manual
March 1999
09front2.fm Page 1 Tuesday, March 2, 1999 11:18 AM
Przeglądanie stron 0
1 2 3 4 5 6 ... 73 74

Podsumowanie treści

Strona 1 - Transmitter

Model RFT9709 TransmitterInstruction ManualMarch 199909front2.fm Page 1 Tuesday, March 2, 1999 11:18 AM

Strona 2

2RFT9709 Transmitter Instruction ManualBefore You Begin continuedProving the Coriolis flowmeterProving Micro Motion flowmeters can be accomplished usi

Strona 3

RFT9709 Transmitter Instruction Manual3Wiring Startup TroubleshootingBefore You Begin MountingInstallationStep 1 Mounting1.1 Location requirements• Mo

Strona 4

4RFT9709 Transmitter Instruction ManualMounting continued1.2 Mounting optionsThe RFT9709 has these installation options for mounting on any flat surfa

Strona 5 - Table of Contents

RFT9709 Transmitter Instruction Manual5Mounting continuedWiring Startup TroubleshootingBefore You Begin Mounting1.4 Optional NEMA-housing installation

Strona 6 - Appendixes

6RFT9709 Transmitter Instruction ManualMounting continuedFigure 1-3. Factory-supplied NEMA-housing dimensionsDimensions ininches(mm)5 5/16(136)Mountin

Strona 7

RFT9709 Transmitter Instruction Manual7Wiring Startup TroubleshootingBefore You Begin MountingInstallationStep 2 Wiring2.1 General guidelinesFigure 2-

Strona 8

8RFT9709 Transmitter Instruction ManualWiring continued2.2 Power supply wiring and groundingFor power-supply wiring and grounding, follow these guidel

Strona 9

RFT9709 Transmitter Instruction Manual9Wiring continuedWiring Startup TroubleshootingBefore You Begin Mounting2.3 Sensor wiringThe instructions in thi

Strona 10 - RFT9709 components

10RFT9709 Transmitter Instruction ManualWiring continuedCable typesMicro Motion supplies 9-wire jacketed, shielded, or armored cable, as illustrated i

Strona 11 - Step 1 Mounting

RFT9709 Transmitter Instruction Manual11Wiring continuedWiring Startup TroubleshootingBefore You Begin MountingRemotely-installed temperature detector

Strona 12 - 1.3 Installation in user

09front2.fm Page 2 Tuesday, March 2, 1999 11:18 AM

Strona 13 - 1.4 Optional NEMA-housing

12RFT9709 Transmitter Instruction ManualWiring continuedCable connections to sensor and RFT9709Wiring connections from the sensor to the RFT9709 are m

Strona 14

RFT9709 Transmitter Instruction Manual13Wiring continuedWiring Startup TroubleshootingBefore You Begin MountingFigure 2-5. RFT9709 terminals for senso

Strona 15 - Step 2 Wiring

14RFT9709 Transmitter Instruction ManualWiring continuedFigure 2-6. Wiring to ELITE® CMF sensors0123456789GreenWhiteBrownVioletYellowOrangeBlueGrayRed

Strona 16 - 2.2 Power supply wiring and

RFT9709 Transmitter Instruction Manual15Wiring continuedWiring Startup TroubleshootingBefore You Begin MountingFigure 2-7. Wiring to BASIS® F, Model D

Strona 17 - 2.3 Sensor wiring

16RFT9709 Transmitter Instruction ManualWiring continuedFigure 2-8. Wiring to Model DT sensors0123456789BrownRedClip drain wire backGreenWhiteClip dra

Strona 18

RFT9709 Transmitter Instruction Manual17Wiring continuedWiring Startup TroubleshootingBefore You Begin Mounting2.4 Output wiringOutput wiring terminal

Strona 19 - Remotely-installed

18RFT9709 Transmitter Instruction ManualWiring continuedPrimary and secondary mA outputsPrimary and secondary output signals can be independently conf

Strona 20 - Cable connections to

RFT9709 Transmitter Instruction Manual19Wiring continuedWiring Startup TroubleshootingBefore You Begin MountingHART multidrop network wiringThe Bell 2

Strona 21 - *Combined drain wires

20RFT9709 Transmitter Instruction ManualWiring continuedRS-485 outputThe RS-485 physical layer is used for serial communication with the HART or Modbu

Strona 22 - CMF sensors

RFT9709 Transmitter Instruction Manual21Wiring continuedWiring Startup TroubleshootingBefore You Begin MountingFrequency/pulse outputThe frequency/pul

Strona 23 - F, Model D, and DL sensors

Model RFT9709 TransmitterInstruction ManualFor technical assistance, phone the Micro Motion Customer Service Department:• In the U.S.A., phone 1-800-5

Strona 24

22RFT9709 Transmitter Instruction ManualWiring continuedSlug-flow inhibitThe RFT9709 senses density outside user-selected limits. The output holds at

Strona 25

RFT9709 Transmitter Instruction Manual23Wiring continuedWiring Startup TroubleshootingBefore You Begin MountingExternal zero switch wiringThe RFT9709

Strona 26 - Figure 2-10

24RFT9709 Transmitter Instruction ManualViscosity measurement or pressure compensationThe RFT9709 accepts pressure input signals from a pressure trans

Strona 27 - network wiring

RFT9709 Transmitter Instruction Manual25Wiring continuedWiring instructionsInstructions for wiring the RFT9709 to a pressure transmitter are provided

Strona 28 - Figure 2-12. RS-485 wiring

26RFT9709 Transmitter Instruction Manual09wire.fm Page 26 Monday, March 1, 1999 4:31 PM

Strona 29 - Figure 2-13

RFT9709 Transmitter Instruction Manual27Wiring Startup TroubleshootingBefore You Begin MountingInstallationStep 3 Startup3.1 InitializationAfter wirin

Strona 30 - Control output terminals

28RFT9709 Transmitter Instruction ManualStartup continuedZeroing procedure1. Prepare the flowmeter for zeroing:a. Install the sensor according to the

Strona 31 - Remote-zero switch wiring

RFT9709 Transmitter Instruction Manual29Startup continuedWiring Startup TroubleshootingBefore You Begin Mounting3.3 Event registersEvent registers are

Strona 32 - Sensors affected by

30RFT9709 Transmitter Instruction ManualStartup continued3.4 Totalizer resetMass and volume totalizers cannot be reset independently. When one totaliz

Strona 33

RFT9709 Transmitter Instruction Manual31Wiring Startup TroubleshootingBefore You Begin MountingTroubleshooting4.1 General guidelinesTroubleshooting a

Strona 34

09front2.fm Page 4 Tuesday, March 2, 1999 11:18 AM

Strona 35 - Step 3 Startup

32RFT9709 Transmitter Instruction ManualTroubleshooting continued4.2 Transmitter diagnostic toolsIn some situations, troubleshooting requires use of t

Strona 36 - Diagnosing zero failure

RFT9709 Transmitter Instruction Manual33Troubleshooting continuedBefore You Begin Mounting Wiring Startup Troubleshooting4.3 Interrogation with the Pr

Strona 37 - Parameters that affect

34RFT9709 Transmitter Instruction ManualTroubleshooting continuedFigure 4-2. ProLink® PC-Interface connections1. If necessary, add resistance in the l

Strona 38 - 3.5 Process measurement

RFT9709 Transmitter Instruction Manual35Troubleshooting continuedBefore You Begin Mounting Wiring Startup Troubleshooting4.4 Power supplyCheck to be c

Strona 39 - Troubleshooting

36RFT9709 Transmitter Instruction ManualTroubleshooting continuedTable 4-2. Normal resistance for flowmeter circuitsTable 4-3. Input and output rating

Strona 40 - Switch Settings

RFT9709 Transmitter Instruction Manual37Troubleshooting continuedBefore You Begin Mounting Wiring Startup Troubleshooting4.6 Master resetUse the RFT97

Strona 41 - Output test and trim

38RFT9709 Transmitter Instruction ManualTroubleshooting continuedTable 4-4. Default values after a master resetCharacterization variablesDefault Defau

Strona 42 - PC-Interface connections

RFT9709 Transmitter Instruction Manual39AppendixA RFT9709 SpecificationsPerformance specificationsSensor model Mass flow accuracy1ELITE liquidgas±0.10

Strona 43 - Installation Step 2

40RFT9709 Transmitter Instruction ManualRFT9709 Specifications continuedFunctional specificationsOutputsAnalogTwo independently configured analog outp

Strona 44

RFT9709 Transmitter Instruction Manual41RFT9709 Specifications continuedCommunicationSwitches on the RFT9709 allows selection of the Bell 202 standard

Strona 45 - 4.7 Customer service

RFT9709 Transmitter Instruction ManualiTable of ContentsBefore You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1About

Strona 46

42RFT9709 Transmitter Instruction ManualRFT9709 Specifications continuedLow-flow cutoffFlow values below the user-defined low-flow cutoff cause digita

Strona 47 - A RFT9709 Specifications

RFT9709 Transmitter Instruction Manual43RFT9709 Specifications continuedHazardous area approvalsWhen properly installed with an approved sensor, the R

Strona 48 - Functional specifications

44RFT9709 Transmitter Instruction Manual09specs.fm Page 44 Tuesday, March 2, 1999 9:30 AM

Strona 49 - Input for pressure

RFT9709 Transmitter Instruction Manual45AppendixB Ordering InformationRFT9709 model number matrixCode Transmitter modelRFT9709 RFT9709 transmitterCode

Strona 50

46RFT9709 Transmitter Instruction ManualOrdering Information continuedMicro Motion instruction manualsTo obtain any of the Micro Motion instruction ma

Strona 51 - Hazardous area approvals

RFT9709 Transmitter Instruction Manual47AppendixC Switch SettingsC.1 Configuration switchesSwitches on the RFT9709 (see Figure C-1) control the follow

Strona 52

48RFT9709 Transmitter Instruction ManualSwitch Settings continuedTable C-1. Communications configurationInstructionsBefore beginning, make note of the

Strona 53 - B Ordering Information

RFT9709 Transmitter Instruction Manual49Switch Settings continuedC.3 Fault output settingsFault outputs can be set for downscale or upscale levels.Dow

Strona 54 - OUNDATION

50RFT9709 Transmitter Instruction ManualSwitch Settings continuedSecurity mode 8When security is set for mode 8, the RFT9709 meets security requiremen

Strona 55 - C Switch Settings

RFT9709 Transmitter Instruction Manual51Switch Settings continuedFigure C-2. Diagnostic LED and zero buttonTo verify the transmitter is in security mo

Strona 56

iiRFT9709 Transmitter Instruction ManualTable of Contents continuedTroubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 57 - Table C-2. Security modes

52RFT9709 Transmitter Instruction Manual09switch.fm Page 52 Tuesday, March 2, 1999 9:36 AM

Strona 58 - Security mode 8

RFT9709 Transmitter Instruction Manual53AppendixD Open Collector ConfigurationIf desired, the RFT9709 frequency/pulse and control outputs can be confi

Strona 59 - Diagnostic LED and zero

54RFT9709 Transmitter Instruction Manual09openc.fm Page 54 Tuesday, March 2, 1999 9:41 AM

Strona 60

RFT9709 Transmitter Instruction Manual55AppendixE Decontamination and Return Goods Policy – USAA Return Material Authorization Number (RMA) must be ob

Strona 61 - Configuring open collector

RMA number:Equipment to be returned:By:Job title:Company name:Phone number:FAX number:Date:Decontamination/Cleaning StatementSubstance 1 Substance 2Co

Strona 62

RFT9709 Transmitter Instruction Manual57AppendixF Decontamination and Return Goods Policy – EuropeTo conform with Dutch ARBO regulations and to provid

Strona 63 - Return Goods Policy – USA

Repair and/or Warranty Request SheetCompany: Contact:Address:Tel No: Fax No:Reference / Order numbers Installation dataCustomer reference Delivery dat

Strona 64 - IMPORTANT:

RFT9709 Transmitter Instruction Manual59Page numbers in bold indicate illustrations.IndexAAbout this manual 1Accuracy 39Agency approvalsapproved are

Strona 65 - Return Goods Policy – Europe

60RFT9709 Transmitter Instruction ManualIndex continuedDownscaleconfiguration switches 49fault indication 32, 42DP cell. See Pressure transmitterDT

Strona 66

RFT9709 Transmitter Instruction Manual61Index continuedMaster resetcommunications configuration 48default characterization and configuration values

Strona 67

RFT9709 Transmitter Instruction ManualiiiTable of Contents continuedTablesTable 2-1 Sensor-wiring terminal designations. . . . . . . . . 13Table 2-2

Strona 68

62RFT9709 Transmitter Instruction ManualIndex continuedPower supply 8grounding 8, 8pressure transmitter 25specification 42terminals 8troubleshoot

Strona 69 - See also

RFT9709 Transmitter Instruction Manual63Index continuedTemperatureeffect on transmitter 42limits 42mounting location 3Terminals 7intrinsically saf

Strona 70

64RFT9709 Transmitter Instruction Manual09__a.IX Page 64 Tuesday, March 2, 1999 9:52 AM

Strona 71

09back_2.fm Page 65 Tuesday, March 2, 1999 11:40 AM

Strona 72

recycled paperMicro Motion Inc. USAWorldwide Headquarters7070 Winchester CircleBoulder, Colorado 80301Tel (303) 530-8400(800) 522-6277Fax (303) 530-84

Strona 73

ivRFT9709 Transmitter Instruction Manual09__a.TOC Page iv Monday, March 1, 1999 4:20 PM

Strona 74 - Micro Motion Asia

RFT9709 Transmitter Instruction Manual1Wiring Startup TroubleshootingBefore You Begin MountingBefore You BeginAbout this manualThis instruction manual

Komentarze do niniejszej Instrukcji