Micro Motion RFT9709 Instrukcja Obsługi Strona 51

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 50
RFT9709 Transmitter Instruction Manual
43
RFT9709 Specifications
continued
Hazardous area approvals
When properly installed with an approved sensor, the RFT9709
transmitter can be installed in the following areas:
UL
Class I, Div. 2, Groups A, B, C, and D. Provides nonincendive sensor
outputs for use in Class I, Div. 2, Groups A, B, C, and D; or intrinsically
safe sensor outputs for use in Class I, Groups C and D, and Class II,
Groups E, F, and G.
UL Division 2 nonincendive parameters
CSA
Approval pending
Weight
Standard housing 1.5 lb (0.68 kg)
Housed in factory-supplied NEMA-4 (IP65) enclosure 6.5 lb (2.9 kg)
Parameter
Analog output
(Terminals 11-12, 13-14)
Frequency/pulse output
(Terminals 17-18)
V
OC
36.5 V 16 V
I
SC
22 mA 51 mA
C
a
0.135 µf 1.5 µf
L
a
100 mH 37 mH
09specs.fm Page 43 Tuesday, March 2, 1999 9:30 AM